AQUA MATIC SPECIFICATIONS
Performance:
Rated Performance / Product Water Produced: +-15% at 820 PSI / 56.5 bar, 77oF / 25oC & 35,000 PPM TDS typical sea water

Model # Per Hour Per Day
AM 450-1

19 gal/71 lit

450 gal /1,703 lit


Salt Rejection (Chloride Ion):
Minimum 99.2%, Average 99.4%

Product Water Temperature: Ambient to feed water temperature

Pressure Adjustment: Automatically controlled

Salinity Monitoring: Automatic electronic monitoring. Temperature compensated with the digital continuous readout. The salinity monitoring components of the system give a continuous TDS readout in ppm (parts per million), are temperature compensated, and of a fail safe design.

Salinity Range: Designed for seawater use up to 50,000 PPM TDS (NaCl) (typical seawater salinity is 35,000 ppm)

Temperature Range: Max. 122oF / 50oC, Min. 33oF / .5oC

System Feed Water: Flow: 4.5 gpm / 17 lpm
(depending on system)

Reverse Osmosis Membrane: Selected High Rejection/High Yield aromatic tri-polyamid, thin film composite, spiral wound, single pass, high rejection reverse osmosis membrane element.

Chlorine Tolerance: 0.1 PPM

pH Range: 3-11 (typical seawater pH is 8)

System Pressure: Feed Water: Maximum 35 psi / 2.41 bar / 2.46 Kg/cm2

System Operation: Seawater nominal 820 psi / 56.5 bar / 57.66 Kg/cm2

Weight:
Model Number
Modular
Compact
AM 450-1

137 lbs/63 Kg

142 lbs/65 Kg


External Installation Water Connections: Pipe sizes to be supplied by the installer for connection of the Sea Recovery supplied components. The below pipe threads are all American Standard.
Feed Inlet: 3/4" FNPT Female National Pipe Thread
Brine Discharge: 3/4" FNPT Female National Pipe Thread
Product: 3/8" MNPT Male National Pipe Thread

Electrical Requirements: (HP = Horse Power; FLA = Full Load Amperes; LRA = Locked Rotor Amperes - Start Up)

High Pressure Pump Electric Motor:

Phase Hz VAC HP FLA LRA
Single 50 110 3.0 23 136
Single 50 220 3.0 11 68
Three 50 220 3.0 9 40
Three 50 380 3.0 5 20
Single 60 115 3.0 25 136
Single 60 230 3.0 12 68
Three 60 230 3.0 8 35
Three 60 460 3.0 4 18

Booster Pump & Feed Water Electric Motors:
Phase Hz VAC HP FLA LRA
Single 50/60 115 .5 7.4 34
Single 50/60 220/230 .5 3.7 17
Three 50/60 220/230 .5 2 12
Three 50/60 380/460 .5 1 6

Recommended Circuit Breaker: The final system configuration may have a large or different size Booster Pump therefore size your Circuit Breaker accordingly. The below chart is an approximation assuming standard pumps.

Operating Voltage Hz & Phase

Rec. Circuit Breaker Size
115 VAC, 50/60 Hz, 1 Phase
230 VAC, 50/60 Hz, 1 Phase
208/230 VAC, 50/60 Hz, 3 Phase
380 VAC, 50/60 Hz, 3 Phase
460 VAC, 50/60 Hz, 3 Phase

40 Amperes
20 Amperes
10 Amperes
7.5 Amperes
7.5 Amperes