| AQUA MATIC SPECIFICATIONS |  | Performance: Rated Performance / Product Water Produced: +-15% at 820 PSI / 56.5 bar, 77oF / 25oC & 35,000 PPM TDS typical sea water
| Model # | Per Hour | Per Day | AM 450-1
| 19 gal/71 lit
| 450 gal /1,703 lit
| Salt Rejection (Chloride Ion): Minimum 99.2%, Average 99.4%
Product Water Temperature: Ambient to feed water temperature
Pressure Adjustment: Automatically controlled
Salinity Monitoring: Automatic electronic monitoring. Temperature compensated with the digital continuous readout. The salinity monitoring components of the system give a continuous TDS readout in ppm (parts per million), are temperature compensated, and of a fail safe design.
Salinity Range: Designed for seawater use up to 50,000 PPM TDS (NaCl) (typical seawater salinity is 35,000 ppm)
Temperature Range: Max. 122oF / 50oC, Min. 33oF / .5oC
System Feed Water: Flow: 4.5 gpm / 17 lpm (depending on system)
Reverse Osmosis Membrane: Selected High Rejection/High Yield aromatic tri-polyamid, thin film composite, spiral wound, single pass, high rejection reverse osmosis membrane element.
Chlorine Tolerance: 0.1 PPM
pH Range: 3-11 (typical seawater pH is 8)
System Pressure: Feed Water: Maximum 35 psi / 2.41 bar / 2.46 Kg/cm2
System Operation: Seawater nominal 820 psi / 56.5 bar / 57.66 Kg/cm2
Weight: | | | Compact | AM 450-1
| 137 lbs/63 Kg
| 142 lbs/65 Kg
| External Installation Water Connections: Pipe sizes to be supplied by the installer for connection of the Sea Recovery supplied components. The below pipe threads are all American Standard. | Feed Inlet: | 3/4" FNPT Female National Pipe Thread | | Brine Discharge: | 3/4" FNPT Female National Pipe Thread | | Product: | 3/8" MNPT Male National Pipe Thread | Electrical Requirements: (HP = Horse Power; FLA = Full Load Amperes; LRA = Locked Rotor Amperes - Start Up)
High Pressure Pump Electric Motor:
| Phase | Hz | VAC | HP | FLA | LRA | | Single | 50 | 110 | 3.0 | 23 | 136 | | Single | 50 | 220 | 3.0 | 11 | 68 | | Three | 50 | 220 | 3.0 | 9 | 40 | | Three | 50 | 380 | 3.0 | 5 | 20 | | Single | 60 | 115 | 3.0 | 25 | 136 | | Single | 60 | 230 | 3.0 | 12 | 68 | | Three | 60 | 230 | 3.0 | 8 | 35 | | Three | 60 | 460 | 3.0 | 4 | 18 | Booster Pump & Feed Water Electric Motors: | Phase | Hz | VAC | HP | FLA | LRA | | Single | 50/60 | 115 | .5 | 7.4 | 34 | | Single | 50/60 | 220/230 | .5 | 3.7 | 17 | | Three | 50/60 | 220/230 | .5 | 2 | 12 | | Three | 50/60 | 380/460 | .5 | 1 | 6 | Recommended Circuit Breaker: The final system configuration may have a large or different size Booster Pump therefore size your Circuit Breaker accordingly. The below chart is an approximation assuming standard pumps.
| Operating Voltage Hz & Phase |
| Rec. Circuit Breaker Size | | 115 VAC, 50/60 Hz, 1 Phase 230 VAC, 50/60 Hz, 1 Phase 208/230 VAC, 50/60 Hz, 3 Phase 380 VAC, 50/60 Hz, 3 Phase 460 VAC, 50/60 Hz, 3 Phase
|
| 40 Amperes 20 Amperes 10 Amperes 7.5 Amperes 7.5 Amperes
| |
|